Description
S2 Series Explosion Proof 65-2396RK-05
- Description
- Features
- Applications
- Specifications
- Documentation
- Accessories
- Replacement Sensors
- Calibration Kits
The RKI S2 series gas sensor/transmitters are highly reliable and very cost effective for the detection of common gas hazards. The S2 series are available for LEL, H2 Specific (LEL, and ppm), Oxygen, H2S, CO, and for a variety of toxic gases. The transmitters for LEL, H2 Specific, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame arrestors, and approved for use in hazardous areas (Class l, Groups B, C, D). An optional non-explosion proof version is available for oxygen, H2S, CO, and CO2 in Class 1 Div 2. LEL sensors are available using catalytic bead and infrared technologies.
The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in Class I, Div. 2 hazardous locations. Sensors available for NH3, SO2, PH3, AsH3, and HCN.
The S2 transmitters can be used either indoors or outdoors. The flame arrestors for the explosion-proof versions utilize a patented coating which make them water repellent. Splash guards are also available for use in very wet environments. An optional stainless steel junction box is available for corrosive environments.
All of the S2 transmitters are designed to interface with RKI controllers, or with PLC/DCS systems.
- Available gases include LEL, H2S, CO, PPM H2, and CO2
- Toxic gases include NH3, SO2, HCN, and more
- Infrared sensor for combustibles and CO2
- Hydrogen-Specific now available
- Patented water repellent sensor coating
- 4-20 mA output
- Explosion proof construction
- Optional stainless steel junction box
- Petrochemical Plants
- Refineries
- Gas Plants
- Offshore Drilling Platforms
- Water & wastewater treatment plants
- Pulp & paper mills
- Gas, telephone, & electric utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
- Chemical storage buildings
LEL (General Purpose) | LEL (H2 Specific) | H2 PPM (Hydrogen) | O2 (Oxygen) | H2S (Hydrogen Sulfide) | CO (Carbon Monoxide) | CH4 (Methane) | HC (Hydrocarbons) | CO2 (Carbon Dioxide) | |
---|---|---|---|---|---|---|---|---|---|
Part # | 65-2405RK | 65-2451RK | 65-2443-500 | 65-2322RK | 65-2331RK | 65-2336RK | 65-2394RK-CH4 | 65-2394RK-HC | 65-2396RK-02 |
65-2405RK-05 | 65-2451RK-05 | 65-2443-1000 | 65-2396RK-03 | ||||||
65-2443-2000 | 65-2396RK-05 | ||||||||
65-2396RK-10 | |||||||||
Sensor | Catalytic | Metal oxide semiconductor | Galvanic cell | Electrochemical | Infrared | ||||
Measuring Range | 0-100% LEL | 0-100% LEL (H2 Specific) | 0-500 ppm | 0-25% Vol. | 0-100 ppm | 0-300 ppm | 0-100% LEL | 0 - 5000 ppm | |
0-1000 ppm | 0 - 5% Vol. | ||||||||
0-2000 ppm | 0 - 50% Vol. | ||||||||
0 - 100% Vol. | |||||||||
Lower Detectable Limit (LDL) | 2% of full scale | 0.1% Vol. | 2% of full scale | ||||||
Accuracy (whichever is greater) | ± 5% of reading or ± 2% LEL | ± 10% of full scale | ± 0.5% O2 | ± 5% of reading ± 2 ppm H2S | ± 5% of reading ± 5 ppm CO | ± 5% of reading or ± 2% of full scale | |||
Response Time (T-90) | 30 Seconds | 20 Seconds | 45 Seconds | 90 Seconds | 60 Seconds | 90 Seconds | 30 Seconds | 30 Seconds | 30 Seconds |
Max Current Draw (24VDC) | 70 mA (power wires) | 25 mA max, 2 wires | 60 mA (power wires) | ||||||
25 mA (signal wires) 3 wires | 25 mA (signal wires) 3 wires | ||||||||
Life Expectancy | 2 to 3 years with normal exposure to flammable gas | 3-5 years with normal service | 5 years plus with normal service | 2-3 years with normal service | 5 years plus with normal service | ||||
Operating Environment | |||||||||
Location | Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D. | ||||||||
Temperature | -40°F to 167°F | -4°F to 104°F | -4°F to 113°F | -40°F to 104°F | 23°F to 104°F | -40°F to 122°F | |||
-40°C to 75°C | -20°C to -40°C | -20°C to 45°C | -40°C to 40°C | -5°C to 40°C | -40°C to 50°C | ||||
Humidity | 0 - 99% RH, non condensing | ||||||||
Housing | |||||||||
Housing J Box | Cast aluminum explosion proof, optional stainless steel J-box available | ||||||||
Sensor | Stainless steel explosion proof | ||||||||
Controls | |||||||||
Zero | Sets transmitter output to 4 mA with zero output from sensor | ||||||||
Span | Sets transmitter output to proper level when span gas is applied | ||||||||
Output | 4 - 20 mA signal | ||||||||
Operating Voltage | 11 VDC to 30 VDC | 19 VDC to 30 VDC | 19-30 VDC (250 OHMS impedance max) | 11 VDC to 30 VDC | |||||
Approvals | 65-2405RK: UL | 65-2451RK: UL | 65-2443-500: UL | CSA NRTL | C UL US | ||||
65-2405RK-05: CSA | 65-2451RK-05: CSA | 65-2443-1000: UL | |||||||
65-2443-2000: UL | |||||||||
65-2443-500-05: CSA | |||||||||
65-2443-1000-05: CSA | |||||||||
65-2443-2000-05: CSA | |||||||||
Controllers | Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems | ||||||||
Warranty | One year materials and workmanship |
S2 Wiring Matrix | ||||
---|---|---|---|---|
S2 Transmitter | Number of Wires to Controller | Maximum Distance to Controller | ||
18 AWG wire | 16 AWG wire | 14 AWG wire |
||
LEL / IR / CO2 | 3 | 2500 ft. | 5000 ft. | 8000 ft. |
Oxygen | 2 | 2500 ft. | 5000 ft. | 8000 ft. |
H2S | 2 | 2500 ft. | 5000 ft. | 8000 ft. |
CO | 2 | 2500 ft. | 5000 ft. | 8000 ft. |
Toxics | 2 | 2500 ft. | 5000 ft. | 8000 ft. |