RKI SDM-E2 cal station, 58AL cyl 25 ppm H2S / 50 ppm CO / 50% LEL CH4 / 12% O2 in N2 & 103L steel cyl 10 ppm isobutylene in Air

Call for Price

Description

Also includes two demand flow regulators, AC adaptor, flash drive, USB cable, tubing, and installation CD.

RKI SDM-E2 Calibration Station



The SDM-E2 is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand-alone device for charging, calibration and bump testing, with all records automatically stored for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi Module System

The SDM-E2 can also be connected to a PC for automated calibration bump testing and archiving of datalog data from Eagle 2 instruments. Up to ten SDM-E2 docking stations can be connected simultaneously using USB cables. The SDM-E2 is also equipped with two gas ports to connect up to two calibration gas mixtures to the multi module system.
  • Stand Alone Station
    • Stand-alone station (no connection to PC Required)
    • Charging (NiMH batteries)
    • Calibration
    • Bump Test
    • Save bump test and calibration records
    • Bump test and calibration records copy to USB jump drive
    • 2 Calibration gas ports
    • Includes PC software for viewing/archiving bump test and calibration records
  • Multi Module System
    • Multiple modules connected to a PC (10 max)
    • Charging
    • Calibration
    • Bump Test
    • Configure Eagle 2 parameters
    • 2 Calibration gas ports
    • Archive Bump Test and Calibration records
    • Archive data to network location
    • Software controlled data retrieval
    • Automatic calibration/bump test option
    • Windows 7 compatible
Input Power12 VDC
NOTE: AC Adapter with 100 - 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard.
Environmental Conditions• For Indoor Use Only
• -10° C to 40° C, below 80% Relative Humidity, Non-Condensing
Applicable InstrumentEAGLE 2
Memory Capacity64 KB
Maximum Record Size256 bytes
Maximum Number of Records Saved200
Number of Calibration Gas CylindersUp to two calibration gas cylinders per bump test or calibration at a time
NOTE: If your EAGLE 2 contains more than one non-standard gas, more than two gas cylinders may be needed to complete a bump test or calibration.
Standard Accessories• AC Adapter
• USB Flash Drive
• Single Module Data Viewer Software
• SDM-E2 Docking Station PC Controller Software
• Inlet Air Filter
• Instruction Manual
• 10 Foot Long Exhaust Tube
• Two 3 Foot Long Tubes for GAS 1 and GAS 2 Fittings
• 3 T-Fittings for PC Controlled Configuration
• Check Valve for PC Controlled Configuration
• USB Cable, Type A to Type B

Additional information

Weight 1 lbs