Description
Calibration kit includes 34L cyl 50% LEL CH4/Air, regulator, cal cup & tubing.
RKI GP-03 72-0038-56
- Description
- Features
- Applications
- Specifications
- Documentation
- Spare Parts
- Accessories
- Replacement Sensors
- Calibration Kits
- Calibration Stations
The 03 Series single gas monitors are designed for LEL, O2, H2S, or CO detection. Individuals need personal protection in hazardous areas at all times without adding extra bulky equipment, and the 03 Series can provide that kind of protection at an affordable price. The GP-03 model is a personal single gas monitor designed for protection from exposure to combustible hydrocarbons.
- Available for LEL, O2, H2S, or CO
- Operates 3,000 hours on alkaline (GP-03 up to 35 hours)
- Pocket size 2.1” x 2.6” x 0.9”
- Lightweight, 2.8 ounces
- IP-67
- Data log from 5 to 300 hours
- Audible / visual / vibration alarms
- Automatic backlight
- Peak Hold, STEL & TWA
- Intrinsically safe, ATEX & CSA
- 3 Year warranty H2S & CO
- 2 Year warranty LEL & O2
- Hazardous Material
- Mining
- Tunnels
- Refineries / Petrochemical
- Water / Wastewater Treatment
- Pharmaceuticals
- Utilities
- Chemical Plants
- Fire Services
Model Name | GP-03 |
Gas Detected | Combustible gas |
Detection Principle | Catalytic combustion |
Detection Range (Increments) | 0 – 100% LEL (1% LEL increments) |
Alarm Set Points | 1st 10% LEL |
2nd 50% LEL | |
Over 100% LEL | |
Alarm Types | Gas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA |
Trouble alarms: Sensor connection, low battery circuit failure, and calibration range error | |
Alarm Methods | Gas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration |
Trouble alarm: Flashing LED’s, intermittent buzzer, and display of error message | |
STEL & TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration | |
Gas Sampling | Diffusion |
Response Time | T90 in 30 seconds |
Accuracy which ever is greater | ± 5 of reading or ± 2% LEL |
Power Options | Alkaline dry cell (2-AAA size) |
Ni-MH battery | |
Continuous Operation | Alkaline: 35 hrs |
Ni-MH: 30 hrs | |
Safety Rating | ATEX/IECEx approved. CSA classified, “C/US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D |
Dimensions & Weight | 2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g) |
Display | Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon |
Operating Temp. & Humidity | -4°F ~ 122°F (-20°C ~ 50°C); Humidity below 90% RH (non-condensing) |
Standard Accessories | - Rubber protective boot - Alligator clip - Data logging software - Alkaline batteries |
Optional Accessories | - Calibration adapter - Charger unit - Calibration kit - Belt clip - Data logging download cable - Wrist strap |
Special Functions | - Manual backlight for LCD (automatically lit during alarm) - Peak hold, STEL & TWA |
Warranty | 2 Year warranty |
03 Series Quick Reference Guide
03 Series Datasheet
GP-03 Operator's Manual
03 Series User Setup Program Operator's Manual
03 Series Data Logger Management Program Operator's Manual
03 Series Datasheet
GP-03 Operator's Manual
03 Series User Setup Program Operator's Manual
03 Series Data Logger Management Program Operator's Manual