Honeywell MIDAS High Temperature Pyrolyzer Module

$2,293.00

Description

MIDAS High Temperature Pyrolyzer Module

Higher Temperature Pyrolyzer MIDAS® transmitters provide detection of C4F6, C5F8 and other gases. Unit includes a snap on pyrolyzer module that operates with any Universal MIDAS® Extractive Transmitter (order separately). Units are powered via direct connection to transmitter unit. Consult Honeywell Analytics for additional gases detectable with this option. Pyrolyzer includes Pyrolyzer Quick Start Guide and installation screws. Order the PFC cartridge (MIDAS-E-XCF) separately. Order the ventilated top cover (MIDAS-A-103) separately.

MIDAS-T-NP1: The Midas Pyrolyzer allows for the detection of NF3 and other CFX gases. Cost of ownership is low, as the Pyrolyzer has a field replaceable heater assembly with a lifespan of greater than two years. Additionally, the enhanced version of the Midas Pyrolyzer delivers:

• Improved detection accuracy of gas concentrations • Lowered operation temperature that saves power and reduces system stress • Reduced startup time to reach thermal stable state / be ready for gas detection
  • Over 35 gases available with extended 2 year warranty*
  • Smart sensor cartridge with on board ‘e-calibration’ certificate
  • 3 built in relays (Form C) for Alarm 1, 2 and Fault
  • Power over Ethernet (PoE) communication
  • Keypad interface and remote web browser interface
  • Optional Midas Pyrolyzer module that connects to any Midas Gas Detector
  • Password protected menu levels to preserve system integrity
  • Bright LEDs and intuitive icon driven, large multicolor backlit LCD display
  • Factory-calibrated sensors to reduce need for frequent gas testing
  • Isolated 0-22 mA analog output with fault and event reporting
  • Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
  • Robust extractive pump system (2 year lifetime) sampling up to 100 feet
  • CE marked for total immunity to Radio Frequency Interference
  • Reflex® sensor health check for improved safety
  • TempraSureTM temperature compensation technology as appropriate
  • Event logging to review sensor history
  • Detects more than 35 gases error-free
  • Improved visibility and ease of use
  • Easy installation
Transmitter DimensionSize (unit with Sensor)5.91 (H) × 2.56 (W) × 6.02 (D) in (150 × 65 × 153 mm)
Weight (unit with Sensor)1.76 lb (0.8 kg)
NF3 Pyrolyzer DimensionSize (unit with Sensor)2.75 (H) × 2.48 (W) × 3.35 (D) in (70 × 63 × 85 mm)
Weight (unit with Sensor)0.9 lb (0.41 kg)
High-Temperature PFC Pyrolyzer DimensionSize (unit with Sensor)3.9 (H) × 4.0 (W) × 5.5 (D) in (100 × 101 × 140 mm)
Weight (unit with Sensor)3 lb (1.36 kg)
OP3 Pyrolyzer DimensionSize (unit with Sensor)5.2 (H) × 2.4 (W) × 3.9 (D) in (132 × 60 × 98 mm)
Weight (unit with Sensor)2.65 lb (1.20 kg)
NP1 Pyrolyzer DimensionSize (unit with Sensor)5.02 (H) × 2.56 (W) × 5.29 (D) in (128 × 65 × 134 mm)
Weight (unit with Sensor)1.8 lb (0.81 kg)
Power RequirementsOperating Voltage24VDC, -15 to +10%
Operating Voltage with Power over Ethernet (PoE)48 VDC via PoE
Power ConsumptionTransmitter Unit<5 W
With Pyrolyzer (Option)<12.95 W
With Lonworks<8 W
With Lonworks and Pyrolyzer<15.95 W
OutputsVisualAlarm, Power and Fault LEDs, LCD display with all gas readings and events
Relays3 relays for Alarm1, Alarm 2 and Fault rated 30VDC, 1 A or 125VAC, 0.5 A; configurable NO or NC, latched or unlatched
Analog3 wire sink, 3 wire source or 4 wire fully isolated, 0 to 21mA
Digital CommunicationsModbus, TCP Ethernet, Power over Ethernet (PoE), Lonworks
Service PortRS232C, PPP protocol
Certification and SpecificationCE marked Meets EN 50270:2006 (Type2) and EN 61000-6-4:2007 ETL approved UL 61010-1 Ed:3 IEEE 802.3af-2003
PerformanceRefer to Individual Cartridge Datasheets
Transport SystemFlow Rate500 mL/min
Transport Time2 to 30 seconds maximum
Sample Line Tubing0.125 in ID × 0.25 in OD
Tubing LengthUp to 100 ft (30 m) with FEP tubing
Exhaust Line Tubing0.25 in ID × 0.375 in OD
Exhaust LengthUp to 100 ft (30m)
Ambient PointIn line air filter required
Operating TemperatureUnit with Sensor32° to 104°F (0° to 40°C)
Unit with Sensor and Pyrolyzer32° to 86°F (0° to 30°C)
Wiring Requirement4-20mA2 wire, 14 AWG maximum
DigitalCAT5 Cable or equivalent; RJ45 connector
Gas Concentration Display and InterfaceInstrument4-digit alphanumeric display with separate units, flow rate bar graph and other icon driven indicators
4 button interface keypad
RemoteOption for PC / PDA Internet browser access via Ethernet
WarrantyTransmitter Unit1 year
Sensor cartridge1 year standard, 2 years extended warranty
Expected Pyrolyzer LifeMIDAS-T-00P: 1 year
MIDAS-T-NP1: 2 years
Installation DetailsMountingWall mounted using pre-drilled holes on chassis. Options for DIN rail or vertical bracket mounting.
RemoteCover: Painted steel
Chassis/Mounting Bracket: Zinc plated steel

Additional information

Weight 1.8 lbs
Dimensions 5.29 × 2.56 × 5.02 in