GX-6000, 6 Gas Meter, LEL / O2 / H2S / CO / VOC’s (0 – 6,000 ppm PID) / NO2, 72-6ABK-C

$3,555.00

SKU: 72-6ABK-C Categories: , , , Tags: ,

Description

Simply put, the GX-6000 is a game changer. This powerful hand-held PID gas monitor is capable of simultaneously monitoring up to 6 gases.

6 Gas Monitor

  • PID gas monitor with simultaneous detection and display.
  • Dual VOC display with 2 PID sensors installed.
  • Monitor the standard 4 confined space gases which include combustibles, O2, CO, & H2S as well as carbon tetrachloride, acrylonitrile, chloroform, methanol, refrigerants (R-143, R-132A), and more.
  • GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.


Safety Features

The GX-6000 is equipped with a strong internal sample pump in addition to advanced safety features.

  • Man-down alarm
  • Panic alarm
  • LED flashlight
  • Large auto rotating LCD display


PID Gas Monitor

Long life 11.7 eV lamp now available, Typical 9 to 12 month life.

The GX-6000 is the only multi-gas instrument with an 11.7 PID sensor option. Traditional solutions include a single gas monitor with an 11.7 PID sensor. If there are other requirements like confined space safety, a second instrument would be required. The GX-6000 provides the flexibility to configure one instrument for multiple applications. This reduces the need to purchase separate instruments for specific applications.

The GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.

  • 0 – 1000 ppm PID with 11.7 eV lamp smart sensor
  • 30 of the commonly used VOC’s.
  • 8 of the most recently used VOC’s.


Reliable and Durable

The GX-6000 is a rugged personal PID gas monitor built for the nastiest environments. Most noteworthy, it is equipped with a removable impact-resistant rubber boot.

  • Dust and water resistant enclosure with an IP-67 rating.
  • 5 bright LED lights on 3 sides of the instrument.
  • View Alarms easily from a variety of perspectives.
  • Vibration and loud audible alarm for immediate notification.


Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene.
  • 6 Operating modes
  • Smallest 6 gas sample draw
  • 2 Interchangeable smart sensor slots
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67 design
  • Interchangeable battery packs (Li-ion / alkaline)
  • Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours; 8 hours operation with alkaline pack
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus
  • Confined space entry
  • Hazmat response teams
  • Arson investigation
  • Remediation sites
  • Perimeter monitoring
  • Leak detection
  • Landfill monitoring
  • Wing tank entry
Common Specifications
Alarm TypesGas alarmMan-downTrouble
Low and high adjustable1st – self reset
2nd – latching
Low flow Sensor connection Low battery Circuit error Calibration range
Sample MethodSample draw pump, flow rate 0.45 LPM, 50 foot sample range
DisplayDigital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Audible Alarm95 dB at 1 ft.
LanguagesEnglish, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
Continuous Operation14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack)
Operating Temp. & Humidity-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
Dimensions2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack)
Case MaterialDust and water resistant with IP-67 approval (exclude sample hose and probe)
Safety Design / ApprovalsExplosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking
Standard Features- 2 Smart sensors slots auto recognize sensor changes
- Library of over 600 VOC’s User defined VOC list.
- Up to 30 frequently used Recent VOC list for last 8 selected gases
- Pump and circuit status indicators
- User & station ID selection menu
- Datalogging (interval, alarm trend, station and user ID)
- Snap logging – on demand data logging
- Demand zero / Auto zero BUMP and CAL expiration alarm
- Flashlight
- IrDA communication
- LEL sensor protection mode
Standard Accessories• Rubber boot
• Belt clip
• Hand strap
• Tapper nozzle
• Probe with hydrophobic & dust filter 3’ teflon lined hose
• Benzene pre-filter tubes and holder (benzene versions)
Optional Accessories• SDM-6000 calibration station
• Bundles with instrument carrying case and accessories
• Flexible probes
• Up to 50 foot sample hoses
• Filter set
• IrDA cable
WarrantyTwo years material (including sensors) and workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp)
Gases & Detectable Ranges
GasMeasuring RangeReading IncrementAlarm Set PointsAccuracy (whichever is greater)
PID Sensors
10.6 Lamp600 VOC’s0 – 50,000 ppb1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb)A1: 5,000 ppb± 10% of reading, ± 1 digit
A2: 10,000 ppb
0 – 6,000 ppm0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm)A1: 400 ppm
A2: 1,000 ppm
10.0 LampBenzene Specific0.1 – 50 ppm0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm)No Alarms
300 VOC’s0 – 100 ppm0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm)A1: 5 ppm
A2: 10 ppm
11.7 LampHigh Voltage Lamp0 – 1000 ppm0.1 ppmA1: 400 ppm
A2: 1,000 ppm
Galvanic
Oxygen (O2)0 – 40.0% Vol.0.1% Vol.A1: 19.5 Vol.± 0.5% O2
A2: 23.5 Vol.
Electro Chemical
Carbon Monoxide (CO)0 – 500 ppm1 ppmA1: 25 ppm± 5% of reading or ± 5 ppm
A2: 50 ppm
TWA 25 ppm
STEL 200 ppm
Hydrogen Sulfide (H2S)0 – 100.0 ppm0.5 ppmA1: 5.0 ppm± 5% of reading or ± 2 ppm
A2: 30.0 ppm
TWA 1.0 ppm
STEL 5.0 ppm
Toxics (EC Sensors)
Ammonia (NH3)0 – 400.0 ppm0.5 ppmA1: 25 ppm± 10% of reading or ± 5% of full scale
A2: 50 ppm
Chlorine (Cl2)0 – 10.00 ppm0.05 ppmA1: 0.5 ppm
A2: 1.0 ppm
Hydrogen Cyanide (HCN)0 – 15.0 ppm0.1 ppmA1: 5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2)0 – 20.00 ppm0.05 ppmA1: 3 ppm
A2: 6 ppm
Sulfur Dioxide (SO2)0 – 99.90 ppmA1: 2 ppm
A2: 5 ppm
IR Sensors
Carbon Dioxide (CO2)0 – 10,000 ppm20 ppmA1: 5,000 ppm± 5% of reading or ± 2% of full scale
TWA 5,000 ppm
0 – 10.00% Vol0.02%A1: 0.50% Vol
A2: 3.00% Vol
STEL 3.00% Vol
TWA 0.50% Vol
Methane (CH4)0 – 100% LEL 0 – 100% Vol.1% LEL/ 0.5% VolA1: 10% LEL
A2: 50% LEL
Hydrocarbons0 – 100% LEL 0 – 30% Vol.
Catalytic
Hydrocarbons (CH4, std)0 – 100% LEL1% LELA1: 10% LEL± 5% of reading or ± 2% LEL
A2: 50% LEL