Simply put, the GX-6000 is a game changer. This powerful hand-held PID gas monitor is capable of simultaneously monitoring up to 6 gases.
6 Gas Monitor
Safety Features
The GX-6000 is equipped with a strong internal sample pump in addition to advanced safety features.
PID Gas Monitor
Long life 11.7 eV lamp now available, Typical 9 to 12 month life.
The GX-6000 is the only multi-gas instrument with an 11.7 PID sensor option. Traditional solutions include a single gas monitor with an 11.7 PID sensor. If there are other requirements like confined space safety, a second instrument would be required. The GX-6000 provides the flexibility to configure one instrument for multiple applications. This reduces the need to purchase separate instruments for specific applications.
The GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.
Reliable and Durable
The GX-6000 is a rugged personal PID gas monitor built for the nastiest environments. Most noteworthy, it is equipped with a removable impact-resistant rubber boot.
Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene.
6 Gas Monitor
- PID gas monitor with simultaneous detection and display.
- Dual VOC display with 2 PID sensors installed.
- Monitor the standard 4 confined space gases which include combustibles, O2, CO, & H2S as well as carbon tetrachloride, acrylonitrile, chloroform, methanol, refrigerants (R-143, R-132A), and more.
- GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.
Safety Features
The GX-6000 is equipped with a strong internal sample pump in addition to advanced safety features.
- Man-down alarm
- Panic alarm
- LED flashlight
- Large auto rotating LCD display
PID Gas Monitor
Long life 11.7 eV lamp now available, Typical 9 to 12 month life.
The GX-6000 is the only multi-gas instrument with an 11.7 PID sensor option. Traditional solutions include a single gas monitor with an 11.7 PID sensor. If there are other requirements like confined space safety, a second instrument would be required. The GX-6000 provides the flexibility to configure one instrument for multiple applications. This reduces the need to purchase separate instruments for specific applications.
The GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.
- 0 – 1000 ppm PID with 11.7 eV lamp smart sensor
- 30 of the commonly used VOC’s.
- 8 of the most recently used VOC’s.
Reliable and Durable
The GX-6000 is a rugged personal PID gas monitor built for the nastiest environments. Most noteworthy, it is equipped with a removable impact-resistant rubber boot.
- Dust and water resistant enclosure with an IP-67 rating.
- 5 bright LED lights on 3 sides of the instrument.
- View Alarms easily from a variety of perspectives.
- Vibration and loud audible alarm for immediate notification.
Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene.
- 6 Operating modes
- Smallest 6 gas sample draw
- 2 Interchangeable smart sensor slots
- 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
- PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
- Benzene specific version
- PPM Leak Check mode
- LEL sensor protection mode
- Man-down alarm
- Panic alarm • Auto display rotation
- Peak-bar display
- LED Light source
- Internal sample pump
- Light weight, small, rugged IP-67 design
- Interchangeable battery packs (Li-ion / alkaline)
- Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours; 8 hours operation with alkaline pack
- Field replaceable sensors, batteries, filters and pump
- Intrinsically safe ATEX / IECEx / cCSAus
- Confined space entry
- Hazmat response teams
- Arson investigation
- Remediation sites
- Perimeter monitoring
- Leak detection
- Landfill monitoring
- Wing tank entry
Common Specifications | |||
---|---|---|---|
Alarm Types | Gas alarm | Man-down | Trouble |
Low and high adjustable | 1st – self reset 2nd – latching | Low flow Sensor connection Low battery Circuit error Calibration range | |
Sample Method | Sample draw pump, flow rate 0.45 LPM, 50 foot sample range | ||
Display | Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases | ||
Audible Alarm | 95 dB at 1 ft. | ||
Languages | English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian | ||
Continuous Operation | 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack) | ||
Operating Temp. & Humidity | -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing | ||
Dimensions | 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) | ||
Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) | ||
Safety Design / Approvals | Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking | ||
Standard Features | - 2 Smart sensors slots auto recognize sensor changes - Library of over 600 VOC’s User defined VOC list. - Up to 30 frequently used Recent VOC list for last 8 selected gases - Pump and circuit status indicators - User & station ID selection menu - Datalogging (interval, alarm trend, station and user ID) - Snap logging – on demand data logging - Demand zero / Auto zero BUMP and CAL expiration alarm - Flashlight - IrDA communication - LEL sensor protection mode |
||
Standard Accessories | • Rubber boot • Belt clip • Hand strap • Tapper nozzle • Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions) |
||
Optional Accessories | • SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable |
||
Warranty | Two years material (including sensors) and workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp) |
Gases & Detectable Ranges | |||||
---|---|---|---|---|---|
Gas | Measuring Range | Reading Increment | Alarm Set Points | Accuracy (whichever is greater) | |
PID Sensors | |||||
10.6 Lamp | 600 VOC’s | 0 – 50,000 ppb | 1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) | A1: 5,000 ppb | ± 10% of reading, ± 1 digit |
A2: 10,000 ppb | |||||
0 – 6,000 ppm | 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) | A1: 400 ppm | |||
A2: 1,000 ppm | |||||
10.0 Lamp | Benzene Specific | 0.1 – 50 ppm | 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) | No Alarms | |
300 VOC’s | 0 – 100 ppm | 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) | A1: 5 ppm A2: 10 ppm |
||
11.7 Lamp | High Voltage Lamp | 0 – 1000 ppm | 0.1 ppm | A1: 400 ppm | |
A2: 1,000 ppm | |||||
Galvanic | |||||
Oxygen (O2) | 0 – 40.0% Vol. | 0.1% Vol. | A1: 19.5 Vol. | ± 0.5% O2 | |
A2: 23.5 Vol. | |||||
Electro Chemical | |||||
Carbon Monoxide (CO) | 0 – 500 ppm | 1 ppm | A1: 25 ppm | ± 5% of reading or ± 5 ppm | |
A2: 50 ppm | |||||
TWA 25 ppm | |||||
STEL 200 ppm | |||||
Hydrogen Sulfide (H2S) | 0 – 100.0 ppm | 0.5 ppm | A1: 5.0 ppm | ± 5% of reading or ± 2 ppm | |
A2: 30.0 ppm | |||||
TWA 1.0 ppm | |||||
STEL 5.0 ppm | |||||
Toxics (EC Sensors) | |||||
Ammonia (NH3) | 0 – 400.0 ppm | 0.5 ppm | A1: 25 ppm | ± 10% of reading or ± 5% of full scale | |
A2: 50 ppm | |||||
Chlorine (Cl2) | 0 – 10.00 ppm | 0.05 ppm | A1: 0.5 ppm | ||
A2: 1.0 ppm | |||||
Hydrogen Cyanide (HCN) | 0 – 15.0 ppm | 0.1 ppm | A1: 5 ppm | ||
A2: 10 ppm | |||||
Nitrogen Dioxide (NO2) | 0 – 20.00 ppm | 0.05 ppm | A1: 3 ppm | ||
A2: 6 ppm | |||||
Sulfur Dioxide (SO2) | 0 – 99.90 ppm | A1: 2 ppm | |||
A2: 5 ppm | |||||
IR Sensors | |||||
Carbon Dioxide (CO2) | 0 – 10,000 ppm | 20 ppm | A1: 5,000 ppm | ± 5% of reading or ± 2% of full scale | |
TWA 5,000 ppm | |||||
0 – 10.00% Vol | 0.02% | A1: 0.50% Vol | |||
A2: 3.00% Vol | |||||
STEL 3.00% Vol | |||||
TWA 0.50% Vol | |||||
Methane (CH4) | 0 – 100% LEL 0 – 100% Vol. | 1% LEL/ 0.5% Vol | A1: 10% LEL A2: 50% LEL |
||
Hydrocarbons | 0 – 100% LEL 0 – 30% Vol. | ||||
Catalytic | |||||
Hydrocarbons (CH4, std) | 0 – 100% LEL | 1% LEL | A1: 10% LEL | ± 5% of reading or ± 2% LEL | |
A2: 50% LEL |
GX-6000 Datasheet
GX-6000 PID Datasheet
GX-6000 Operator's Manual
GX-6000 PID Operator's Manual
GX-6000 Datalogging Manual
GX-6000 PID Datasheet
GX-6000 Operator's Manual
GX-6000 PID Operator's Manual
GX-6000 Datalogging Manual