Description
Beacon 110 72-2110RK
Gas detection should not be complicated. The Beacon 110 is gas detection simplified.
The Beacon 110 is a powerful, low cost fixed system controller for one point of gas detection. It is microprocessor controlled, versatile, simple to install and operate, and priced to be the industry’s best value single gas detection controller. It is capable of accepting RKI sensors directly for LEL level combustibles, Oxygen, Hydrogen Sulfide, or Carbon Monoxide. The Beacon 110 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 110 housing, or can be wired remote from the controller.
The 10 amp rated relays are strong enough to directly power external alarms and horns. The digital display has backlighting and simultaneous readout of the gas type and concentration.
The Beacon 110 is also housed in a NEMA 4X rated case for a weather tight seal. This case design complies with lock out / tag out standards and can be fully secured. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 110 ships complete with a wall mounting kit for easy installation.
RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilized with the Beacon 110, providing gas monitoring protection for almost any application.
- Low cost versatile solution
- Compact, weatherproof, NEMA 4X enclosure
- 115/220 VAC or 24 VDC operation
- Long life sensors (2+ years typical)
- Accepts RKI LEL/O2/H2S/CO direct connect sensors
- Accepts any 4-20 mA transmitter
- Audible alarm with reset button
- Two programmable alarm levels
- Built-in trouble alarm with relay
- Relay rating 10 amps, form C
- Provides 4-20 mA output
- Application
- Petrochemical plants
- Refineries
- Water & wastewater treatment pants
- Pulp & paper mills
- Gas, telephone, & electric utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
- HVAC
Physical | |
Dimensions | Height: 8.5″ (216 mm) |
Width 7.0″ (178 mm) | |
Depth 4.3″ (109 mm) | |
Enclosure | Wall mounting grey polycarbonate with hinged cover. |
Conduit Connection | 3/4″ NPT conduit hubs, 2 provided. 1 for sensor wiring 1 for power & relay wiring |
Wiring Termination | Screw type terminal block 14 gauge max. |
Power | Universal 115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available |
Controls | 3 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset |
Environmental | |
Operating Temp | -4°F to 122°F (-20°C to 50°C) |
Storage Temp | -4°F to 158°F (-20°C to 70°C) |
Relative Humidity | 0 – 100% RH |
Enclosure Rating | NEMA-4X enclosure, waterproof, chemical, and weather resistant. |
Inputs | |
Direct Wired Sensors | LEL Oxygen Carbon Monoxide Hydrogen Sulfide Remote amp not required for less than 500 feet. |
4-20 mA Sensors | Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet |
Sampling Methods | Diffusion and sample draw heads available. |
Outputs | |
Relays | 3 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarms and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off |
4-20 mA | Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel |
24 VDC | 24 VDC (400 mA max) output provided to operate sample drawing adapters or other accessories |
Display | 2 x 8 Alphanumeric display with backlighting. |
Audible | Built-in audible alarm, 94 dB, mounted on enclosure |
Coded output: pulsing = gas alarm, steady = fail | |
Visual | 3 LED’s on the front cover for alarm status indication, and malfunction |
Warranty | One year materials and workmanship |
Approvals | CSA Certified to CSA C22.2 No. 61010-1-04 and UL 61010-1 |
Partial List Of Detectable Gases | Many other gases or ranges available. Contact us for gases or ranges not listed. |
---|---|
Ammonia (NH3) | 0 – 75.0 ppm |
Arsine (AsH3) | 0 – 0.20 ppm |
Boron Trichloride (BCl3) | 0 – 15.0 ppm |
Carbon Dioxide (CO2) | 0 – 1.0 % |
Carbon Monoxide (CO) | 0 – 300 ppm |
Chlorine (Cl2) | 0 – 3.0 ppm |
Chlorine Dioxide (ClO2) | 0 – 1.00 ppm |
Chlorine Trifluoride (ClF3) | 0 – 1.00 ppm |
Combustibles | 0 -100% LEL |
Diborane (B2H6) | 0 – 30.0 ppm |
Fluorine (F2) | 0 – 6.0 ppm |
Hydrogen (H2) | 0 – 2000 ppm |
Hydrogen Chloride (HCl) | 0 – 15.0 ppm |
Hydrogen Fluoride (HF) | 0 – 9.0 ppm |
Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
Nitric Oxide (NO) | 0 -100.0 ppm |
Nitrogen Dioxide (NO2) | 0 – 15.0 ppm |
Nitrogen Trifluoride (NF3) | 0 – 30.0 ppm |
Oxygen (O2) | 0 – 25.0% |
Ozone (O3) | 0 – 1.0 ppm |
Phosphine (PH3) | 0 – 1.0 ppm |
Silane (SiH4) | 0 – 15.0 ppm |
Sulfur Dioxide (SO2) | 0 – 30.0 ppm |
TEOS (Si(OC2H5)4) | 0 -15/30 ppm |