QUESTemp
TSI Quest QUESTemp
The QUESTemp° 32/34/36 Area Heat Stress Monitors are designed to quickly and accurately evaluate potential heat stress environments.
The QUESTemp° 44/46/48N utilizes a waterless wet bulb sensor designed for working environments where daily instrument upkeep is difficult.
QUESTemp 32/34/36
- Utilizes WBGT sensing technology; the standard for heat stress management
- Traditional wet bulb sensing technology
- Convenient stay time parameters per multiple standards help determine work-rest ratios
- IP 54 ingress rating helps protect unit from exposure to dirt, dust, oil and water
- Designed to withstand the rigors of everyday use in demanding environments
- Utilizes WBGT sensing technology; the standard for heat stress management
- Waterless wet bulb sensing technology eliminates daily maintenance
- Convenient stay time parameters per multiple standards help determine work-rest ratios
- IP 54 ingress rating helps protect unit from exposure to dirt, dust, oil and water
- Designed to withstand the rigors of everyday use in demanding environments
QUESTemp 32/34/36
QUESTemp 44/46
QUESTemp 48N
Measurements | Globe, dry bulb, wet bulb, WGBTin, WGBTout, WGBT weighted average (if 3 sensor sets), relative humidity, Heat Index, Humidex. | |
Temperatures given in Celsius or Fahrenheit. | ||
Data Logging | Records and prints all measurements at user selected interval of 1, 2, 5, 10, 15, 30, or 60 minutes. 128K bytes of data memory. | |
Languages | English, French, Spanish, Italian, German. | |
Housing | Designed water resistant to a light rain or mist. If rain is frequent, best practice would be to remote the sensor bar and keep the instrument sheltered. | |
Size | Height | 9.2 in. (23.5 cm) |
Width | 7.2 in. (18.3 cm) | |
Depth | 3.0 in. (7.5 cm) | |
Dimensions include mounted sensor assembly. | ||
Weight | 2.6 lbs. (1.2 kg) with mounted sensor assembly. | |
Sensor Types | Temperature | 1000 ohm platinum RTD |
Humidity | Integrated circuit with capacitive polymer sensor | |
Accuracy | Temperature | ±0.5 C between 0 C and 120 C |
Relative Humidity | ±5% between 20 to 95% (non-condensing) | |
Operating Temperature Range | Sensor Assembly | -5 C to +100 C |
Electronics | -5 C to 60 C | |
Remote Sensor Bars | 2 x 15-pin D-sub jacks are located on the side of the unit for plugging in one or two additional sensor bars by using remote cables up to 200 feet (61 m). The top sensor bar can also be remote with a cable. | |
Power Options | 9V alkaline, 7.2V NiMH rechargeable pack (charged in the unit), or AC adapter wall power cube (AC adapter will operate the unit or recharge the NiMH battery pack). | |
Battery Life | 9V alkaline | 140 hours |
Rechargeable Nickel Metal Hydride | 300 hours | |
(Adding additional sensor bars reduces battery life.) | ||
Charge Time (NiMH Battery Pack) | 16 hours (charge in the unit) | |
Air Probe Accessory (QUESTemp 36 model only) | Range | 0-20 meters per second. 0.1 m/s increments |
Sensor | Omni directional heated thermistor | |
Accuracy | ±(0.1 m/s + 4%) of measurement value | |
Battery Life | 6-8 hours for fully charged NiMH battery | |
Charge Time | 9 hours | |
Product Markings | The year of manufacture is determined by the third character in the instrument's serial number. "A" was manufactured in 2000, "B" in 2001, "C" in 2002, "I" in 2009 and so forth. | |
Batteries | ||
Non-rechargeable battery | Type | Manufacturer |
U9V | Ultralife | |
MN1604 | Duracell | |
522 or EN22 or 6LR61 | Energizer | |
A1604 or BR232 | Rayovac | |
6LR61 or 6AM6 | Panasonic | |
Rechargeable battery | Integral NiMH battery pack type DC2121 | The rechargeable battery may only be recharged with class 2 charger, rated 9 VDC, 1 A max. |
Measurements | Globe, dry bulb temperature, wet bulb temperature, % relative humidity, WGBTin, WGBTout, WGBT weighted average (if 3 sensor sets), and Heat Index / Humidex. | |
Temperatures given in Celsius or Fahrenheit. | ||
Index (QUESTemp 46 only) | ACGIH TLV, U.S. Navy PHEL Charts, Flag Conditions for U.S. Navy/Marine Corp. Ashore, and EPRI | |
Data Logging | Records and prints all measurements at user selected interval of 1, 2, 5, 10, 15, 30, or 60 minutes. 128K bytes of data memory. | |
Languages | English, French, Spanish, Italian, German. | |
Housing | Designed water resistant to a light rain or mist. If rain is frequent, best practice would be to remote the sensor bar and keep the instrument sheltered. | |
Size | Height | 9.2 in. (23.5 cm) |
Width | 7.2 in. (18.3 cm) | |
Depth | 3.0 in. (7.5 cm) | |
Dimensions include mounted sensor assembly. | ||
Weight | 2.6 lbs. (1.2 kg) with mounted sensor assembly. | |
Sensor Types | Temperature | 1000 ohm platinum RTD |
Humidity | Integrated circuit with capacitive polymer sensor | |
Accuracy | Dry Bulb and Globe Temperature | ±0.5 C between 0 C and 120 C |
Waterless Wet Bulb Temperature | Expanded measurement uncertainty of 1.1 C (k=2) between 0 C and 80 C | |
Relative Humidity | ±5% between 20 to 95% (non-condensing) | |
Operating Temperature Range | Sensor Assembly | -5 C to +100 C |
Electronics | -5 C to 60 C | |
Remote Sensor Bars | 2 x 15-pin D-sub jacks are located on the side of the unit for plugging in one or two additional sensor bars by using remote cables up to 200 feet (61 m). The top sensor bar can also be remote with a cable. | |
Power Options | 9V alkaline, 7.2V NiMH rechargeable pack (charged in the unit), or AC adapter wall power cube (AC adapter will operate the unit or recharge the NiMH battery pack). | |
Battery Life | 9V alkaline | 80 hours |
Rechargeable Nickel Metal Hydride | 160 hours | |
(Adding additional sensor bars reduces battery life.) | ||
Charge Time (NiMH Battery Pack) | 16 hours (charge in the unit) | |
Air Probe Accessory | Range | 0-20 meters per second. 0.1 m/s increments |
Sensor | Omni directional heated thermistor | |
Accuracy | ±(0.1 m/s + 4%) of measurement value | |
Battery Life | 6-8 hours for fully charged NiMH battery | |
Charge Time | 9 hours |
Measurements | Globe, dry bulb temperature, wet bulb temperature, % relative humidity, and WGBT Index. | |
Temperatures given in Celsius or Fahrenheit. | ||
Index (displayed stay time with selected index) | ACGIH TLV, U.S. Navy PHEL Charts, Flag Conditions for U.S. Navy/Marine Corp. Ashore | |
Data Logging | Data logging mode records and prints all measurements at user selected interval of 1, 2, 5, 10, 15, 30, or 60 minutes. | |
Event logging mode (1 second record) 128K bytes of data memory. | ||
Languages | English, French, Spanish, Italian, German. | |
Sensors | Dry Bulb Sensor | 1000 Ohm Platinum RTD |
Accuracy and Ranges | ±0.5 from 0 C to 120 C (±0.9 F from 32 F to 248 F) | |
Waterless Wet Bulb (Humidity) Sensor | ||
Accuracy and Ranges | Expanded measurement uncertainty of 1.1 C (k=2) between 0 C and 80 C (32 F and 176 F) | |
Globe Sensor | 1000 Ohm Platinum RTD | |
Accuracy and Ranges | ±0.5 from 0 C to 120 C (±0.9 F from 32 F to 248 F) | |
Relative Humidity Sensor | Integrated circuit with capacitive polymer sensor | |
Accuracy and Ranges | ±5% from 20 to 95% (non-condensing) | |
Operating Temperature Range | Sensor Assembly | -5 C to +100 C |
Electronics | -5 C to 60 C | |
Housing | Designed water resistant to a light rain or mist. If rain is frequent, best practice would be to remote the sensor bar and keep the instrument sheltered. | |
Size | Height | 9.2 in. (23.5 cm) |
Width | 7.2 in. (18.3 cm) | |
Depth | 3.0 in. (7.5 cm) | |
Dimensions include mounted sensor assembly. | ||
Weight | 2.6 lbs. (1.2 kg) with mounted sensor assembly. | |
Remote Sensor Bar | Using a cable, the top sensor bar can be setup for remote measurements, up to 200 feet (61 m). | |
Power | 9V alkaline | |
Battery Life | 9V alkaline | 80 hours |
QUESTemp General Datasheet
QUESTemp 32 Datasheet
QUESTemp 32 User Manual
QUESTemp 34-36 Datasheet
QUESTemp 34-36 User Manual
QUESTemp 44-46 User Manual
QUESTemp 48N User Manual
QUESTemp 32 Datasheet
QUESTemp 32 User Manual
QUESTemp 34-36 Datasheet
QUESTemp 34-36 User Manual
QUESTemp 44-46 User Manual
QUESTemp 48N User Manual
QUESTemp General Comparison
Natural Wet Bulb Models | Waterless Wet Bulb Models | |||||
---|---|---|---|---|---|---|
QTº32 | QTº34 | QTº36 | QTº44 | QTº46 | QTº48N | |
Measurement Parameters | ||||||
Dry bulb, wet bulb and globe temperatures, relative humidity | + | + | + | + | + | + |
Air velocity | optional | optional | ||||
WBGT (indoor) index | + | + | + | + | + | |
WBGT (outdoor) index | + | + | + | + | + | + |
Heat index / HUMIDEX | + | + | + | + | + | |
Temperature reading: Celsius or Fahrenheit | + | + | + | + | + | + |
Data logging intervals: 1, 2, 5, 10, 15, 30 or 60 minutes | + | + | + | + | + | |
Event logging mode | + | |||||
Display languages: Choose from English, French, German, Italian, and Spanish | + | + | + | |||
Operating Temperature Range | ||||||
Sensor assembly: -5° C to 100° C (23° F to 212° F) | + | + | + | + | + | + |
Electronics: -5° C to 60° C (23° F to 140° F) | + | + | + | + | + | + |
Data Management | ||||||
Detection Management Software DMS | + | + | + | + | + | + |
Thermal comfort indices in accordance with ISO 7730 Predicted Mean Vote (PMV) and Predicted Percent Dissatisfied (PPD) | optional | optional | ||||
Output | ||||||
RS-232 serial printer / computer interface; Parallel printer interface | ||||||
Power Source (All include AC power adapter wall power cube) | ||||||
9V disposable batteries; hours of battery life: | 140 | 140 | 140 | 80 | 80 | 80 |
NiMH rechargeable battery; hours of battery life: | 300 | 300 | 300 | 160 | 160 | 160 |
Mechanical | ||||||
D-ring with lanyard attachment. Allows for hands-free monitoring | + | |||||
Tripod mount / remote sensor bar. Allows for up to 61 m (~200 ft) long distance measurement | + | + | + | + | + | + |
IP54 water & dust ingress protection rating | + | + | + | + | + | + |
Case size (including mounted sensor assembly) 23.4 x 18.3 x 7.6 cm (9.2” x 7.2” x 3”) | + | + | + | + | + | + |
Weight: 1.2 kg (2.6 lb) with mounted sensor assembly | + | + | + | + | + | + |
CE Mark | + | + | + | + | + | + |