Calibration Stations
RKI SDM-2012 Calibration Station
RKI’s new SDM-2012 calibration station for the GX-2012 is now available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2012 inside the SDM-2012 calibration module, the GX-2012’s display will indicate whether it’s transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.
Multi Module System
The SDM-2012 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends. Network up to 10 SDM-2012 stations to charge, calibrate, and bump test 10 instruments simultaneously.
User Guide Poster
Each SDM-2012 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a GX-2012. It’s ideal to hang in an instrument shop or wherever the GX-2012 is located.
Multi Module System
The SDM-2012 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends. Network up to 10 SDM-2012 stations to charge, calibrate, and bump test 10 instruments simultaneously.
User Guide Poster
Each SDM-2012 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a GX-2012. It’s ideal to hang in an instrument shop or wherever the GX-2012 is located.
- Stand Alone Station
- Stand-alone station (no PC Required)
- Charging (Li-Ion Battery Pack)
- Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copy to USB jump drive
- Includes PC software for viewing/ archiving bump test and calibration records
- Multi Module System
- Multiple modules connected to a PC (10 max)
- Charging
- Calibration
- Bump Test
- Configure GX-2012 parameters
- 2 Calibration gas ports
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Automatic calibration/bump test option
- Windows 7 compatible
Input Power |
12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard. |
Environmental Conditions |
• For Indoor Use Only • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing |
Applicable Instruments |
GX-2012 and Gas Tracer |
Maximum Number of Records Saved |
200 (stand-alone) |
Number of Calibration Gas Cylinders |
Up to two calibration gas cylinders per bump test or calibration at a time |
Standard Accessories |
|
Showing all 5 results