Touchpoint Pro

Touchpoint Pro

Honeywell’s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint Pro uses a ‘building block’ approach, providing unrivalled flexibility. The building block approach employed by Touchpoint Pro delivers real value by being able to adapt to each unique system requirement. Ease of use and intuitive configuration ensures that installation, set-up and ongoing maintenance costs are reduced, providing a ‘no compromise’ solution designed to reduce the cost of on-site safety.
Flexible architecture

Touchpoint Pro has been designed to deliver flexibility, allowing the system to be freely configured to meet customers’ varying needs. Touchpoint Pro’s modularity means that any system topology can be built, including centralized, distributed I/Os, or a mix of both.

24/7 visibility of system status

Touchpoint Pro’s central controller has a Webserver interface, which can be accessed when it is connected to a network, allowing users to remotely view status and event history, and acknowledge, reset or inhibit channels. This feature offers the possibility of system monitoring and data analysis from a remote location using multiple devices including tablets, smart phones and remote computers.

Simple installation and maintenance

Using a simple building block technique to create your system, Touchpoint Pro offers multiple features that simplifies installation, setup and ongoing maintenance. A key feature to this is the preloaded sensor catalogue, which contains a complete listing of all Honeywell Analytics’ gas sensors, each with a full default configuration setting. A user can choose to configure input channel settings from the sensor catalogue, resulting in a quick and simple three step configuration process. The rest of the configuration will be loaded automatically.

Wide selection of inputs/outputs accepted

The Touchpoint Pro Input/Output plug-in modules can be combined up to a maximum of 16 input modules (64 channels) and 32 output modules (128 channels). Modules can be located in any Touchpoint Pro enclosure and power distribution is via the communication/power Rail. Touchpoint Pro accepts analogue, digital and relay modules making it one of the most flexible controllers available.

Intuitive user interface

The heart of the Touchpoint Pro is the central controller, which includes the user interface. The user interface features a full colour LCD touch screen, and provides engineers with an intuitive solution to system set-up and deployment. Easily accessible icons, supported by drop-down menus ensure that even the most complex of system configurations can be commissioned with efficiency.

Aside from ease of use, Touchpoint Pro’s user interface also includes some valuable aspects that help engineers save time, whilst setting up and commissioning a system.
Small/medium areas of gas detection looking to optimize uptime and reduce risk.
SYSTEMCentralized or distributed system
WALL MOUNT CONTROLLER ENCLOSURE
Dimensions (H x W x D)23.6 in. x 23.6 in. x 11.8 in. (600 mm x 600 mm x 300 mm) (Mild Steel)
31.5 in. x 23.6 in. x 11.8 in. (800 mm x 600 mm x 300 mm) (Mild Steel)
47.2 in. x 23.6 in. x 11.8 in. (1200 mm x 600 mm x 300 mm) (Mild Steel)
WALL MOUNT REMOTE UNIT ENCLOSURE
Dimensions (H x W x D)23.6 in. x 23.6 in. x 11.8 in. (600 mm x 600 mm x 300 mm) (Mild Steel)
31.5 in. x 23.6 in. x 11.8 in. (800 mm x 600 mm x 300 mm) (Mild Steel)
19’’ 5U RACK UNIT
Dimensions (H x W x D)19.02 in. x 8.74 in. x 4.33 in. (483 mm x 222 mm x 110 mm) (Mild Steel)
FLOOR STANDING CABINETS (FRONT OR REAR ACCESS)
Dimensions (H x W x D)78.74 in. x 31.5 in. x 23.62 in. (2000 mm x 800 mm x 600 mm) (Mild Steel)
CONTROL MODULE AND USER INTERFACE
LCD Touch Screen5.7” TFT Color LCD with LED
Backlight (resistive touch screen)
320 x 240 pixels (QVGA) Resolution
Active area 4.54 in. (H) x 3.4 in. (V) (115.2 mm (H) x 86.4 mm (V))
Front Panel Dimension 19.02 in. x 8.74 in. (483 mm x 222 mm)
Operating Temperature-20°C to +55°C
Storage Temperature-20°C to +55°C
Operating Humidity10% to 90% RH (non-condensing)
INPUT SUPPLY
Input Voltage18-32 Vdc (24 Vdc nominal)
Voltage Ripple50 mVp-p (maximum)
CONTROLS AND INDICATORS
Front Panel LEDGreen Power LED
Red Alarm LED
Yellow Fault LED
Yellow Inhibit LED
Front Panel ButtonsAlarm Accept Push Button, Alarm Reset Push Button; Alarm Buzzer
Relay Outputs2 System State Relays
RedundancyRedundant Control Center Board (CCB)
Ring Network
EXTERNAL COMMUNICATION
InterfacesRedundant RS485 Modbus
RTU interface
Ethernet
INPUT/ OUTPUT MODULES COMMON SPECIFICATIONS
Dimensions (H x W x D)1.38 in. x 3.92 in. x 4.51 in. (35.0 mm x 99.5 mm x 114.5 mm)
Power Supply18-32 Vdc (24 Vdc nominal)
DIN rail compatibilityTS-35 / 15
Operating Temperature Range-40°C to 55°C
Operating Humidity Range10 to 90% RH (non-condensing)
InputsUp to 16 Input Modules (64 Input channels) per system
Analog Input Module 4-20 mA;
4-channels for 2 or 3 wire 20 mA detector signals
Analog Input Module mV-Bridge;
4-channels for mV-Bridge signals
Digital Input Module; 4-channels for switched input devices
OutputsUp to 32 Output Modules (128 Output channels) per system Relay Output Module; 4-channels incorporating 4 single pole change over (SPCO) relays
SensorsCatalytic or IR for combustible 4-20 mA transmitters Electrochemical for toxic and Oxygen Conventional smoke, heat and fire detectors
COMMUNICATION / POWER RAIL
Description5, 7, 9, or 10-way Communication / Power Rail consists of 1 DIN Rail, 1 Ring Coupling Module (RCM) and 5, 7, 9, or 10-way backplanes
Power SupplyOperating voltage range - 18 Vdc to 32 Vdc (double-check)
Power Supply mounted on Din-Rail120 W 24 Vdc, 240 W 24 Vdc, 480 W 24 Vdc, Power Supply Redundancy Module (RDN Module), Uninterruptible Power Supply Module (UPS)
BACK-UP BATTERY
Description24 V sealed lead acid battery, 12 Ah or 27 Ah options
Electrical Connection2 x 12 Vdc batteries in series
Dimensions (H x W x D)11.81 in. x 15.55 in. x 8.46 in. (300 mm x 395 mm x 215 mm)
Weight12 Ah version: 34.6 lbs (15.7 kg)
27 Ah version: 55.1 lbs (25 kg)
APPROVALS
ComplianceCompliance with EMC/RFI (EN 50270:2006) and LVD (EN 61010-1:2010)
CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition)
Advanced requirementsATEX Performance Approvals - EN 50271:2010; EN 60079-29-1; EN 45544-1 /-2 /-3; EN 50104:2010
C22.2 No. 152-M1984, FM Std. 6310 and 6320
Highest level of safetyIEC/EN 61508 and EN 50402 SIL2 certification