Touchpoint Plus
Honeywell Touchpoint Plus
The Honeywell Touchpoint Plus is an easily configurable, wall mounted control system that supports up to sixteen channels of gas detection. Its intuitive user interface and modular approach enables you to take control of your safety system and configure it to meet your needs for a wide range of applications.
Designed to work across multiple industries, Touchpoint Plus' modular architecture enables you to customize your system to meet your specific application requirements.
Designed to work across multiple industries, Touchpoint Plus' modular architecture enables you to customize your system to meet your specific application requirements.
Large touchscreen LCD
Built around its intuitive, ergonomic touchscreen, Touchpoint Plus is designed for ease. From here operators can configure, operate and maintain their gas detection system simply and efficiently by simply touching the screen. The multilingual interface simplifies operation, reducing training requirements and costs. Real-time data is presented in an easy to navigate menu system, whilst historical data can be downloaded to monitor developing threats.
At a glance system visibility
When fast and informed decisions need to be made, Touchpoint Plus' full color traffic light style status indicators provide clarity from a distance allowing operators to see system status at-a-glance and make time critical decisions easily.
Unique industrial design
Made of high-impact polymer plastic, Touchpoint Plus is versatile and durable. It is dust-proof, water-proof and has been tested to withstand the toughest environments in which our customers operate - indoors and out. Touchpoint Plus can be directly wall mounted, or for an easier 1-man installation there is an optional mounting plate. Behind the hinged front cover there is plenty of space for wiring and a unique tiered terminal arrangement for easy access. Cable entries are pre-drilled and sealed ready to use, further reducing installation time and cost.
Honeywell Analytics' full system solution
Touchpoint Plus provides a reliable safety solution for small scale gas detection systems across a wide range of applications and industries. As the heart of your gas detection system, Touchpoint Plus is designed to work with Honeywell’s industry leading gas detectors and drive actuators, audible and visual alarms to provide a complete end-to-end, highly configurable safety solution.
Additional Features and Benefits
• Quick and easy setup and use
• Intuitive touchscreen user interface
• Traffic light style status at a glance
• Ergonomic industrial design
• Suited to a wide range of industries
Built around its intuitive, ergonomic touchscreen, Touchpoint Plus is designed for ease. From here operators can configure, operate and maintain their gas detection system simply and efficiently by simply touching the screen. The multilingual interface simplifies operation, reducing training requirements and costs. Real-time data is presented in an easy to navigate menu system, whilst historical data can be downloaded to monitor developing threats.
At a glance system visibility
When fast and informed decisions need to be made, Touchpoint Plus' full color traffic light style status indicators provide clarity from a distance allowing operators to see system status at-a-glance and make time critical decisions easily.
Unique industrial design
Made of high-impact polymer plastic, Touchpoint Plus is versatile and durable. It is dust-proof, water-proof and has been tested to withstand the toughest environments in which our customers operate - indoors and out. Touchpoint Plus can be directly wall mounted, or for an easier 1-man installation there is an optional mounting plate. Behind the hinged front cover there is plenty of space for wiring and a unique tiered terminal arrangement for easy access. Cable entries are pre-drilled and sealed ready to use, further reducing installation time and cost.
Honeywell Analytics' full system solution
Touchpoint Plus provides a reliable safety solution for small scale gas detection systems across a wide range of applications and industries. As the heart of your gas detection system, Touchpoint Plus is designed to work with Honeywell’s industry leading gas detectors and drive actuators, audible and visual alarms to provide a complete end-to-end, highly configurable safety solution.
Additional Features and Benefits
• Quick and easy setup and use
• Intuitive touchscreen user interface
• Traffic light style status at a glance
• Ergonomic industrial design
• Suited to a wide range of industries
General Specification | |
Capacity | Up to 8 channels with base unit, up to 16 channels with expansion unit |
Type of inputs | 2 or 3 wires, mA, mV, max. 15W per channel, max 40W total (with dedicated A/V drive) / 68W total (without dedicated A/V drive) |
Size (wall-mounted version) | 16.8” x 11.8” x 6.1” (426 mm × 300 mm × 156 mm) |
Housing Material | Polycarbonate ABS |
Weight | Max 8.5 kg (18.7 lb), max 17 kg (37.4 lb) with expansion unit |
User Interface (UI) - Controller Only | |
Display | 7’’ color LCD touchscreen |
Graphic User Interface | |
Visual indicators | 3 LEDs for master indicators, LED for each channel |
Green: Normal | |
Yellow: Fault; Inhibit | |
Red: Alarm | |
Audible alarm | ≥ 70dB @ 1m |
Button | Common for reset/mute operation |
Language | English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese |
Power Supply | |
Power AC | 110/220 VAC, 50-60Hz Manual switching |
Power DC | 18 to 32 VDC (+/-10%) Typical 24 VDC |
Power consumption | Max 105W (including detector and external devices), max 210W with expansion unit |
Environmental | |
Operating | -10 °C to +55 °C (14 °F to +131 °F) continuous, up to 95% RH (noncondensing), IP65, and NEMA 4X |
Storage | Instrument -25°C to +60°C. (-13°F to +140°F), up to 95% RH (non-condensing) |
Available I/O Modules | |
4~20mA input | 2 or 3 wire, 2/4/8 channel modules, 10/12/16 with expansion unit |
mV input | Catalytic type flammable gas detectors (Honeywell models). 2/4/8 channel modules, 10/12/16 with expansion unit |
Dual Input | 2 channel mA + 2 channel mV module or 4 channel mA + 4 channel mV module |
Relay output | 12 or 24 relay outputs, NO/C/NC changeover, 1.7A@30VDC/250VAC, user configurable - energized/de-energized, latching/non latching, time delay |
4~20mA output | 4 or 8 isolated repeated mA outputs, 0-22mA, 0-100%FSD = 4-20mA |
Common inputs | Remote reset, remote inhibit |
Common outputs | Four powered A/V outputs for alarms and fault, three common alarm outputs |
Approvals | |
Electromagnetic Compatibility and Electrical Safety | EMC/RFI (EN 50270:2015) |
LVD (EN 61010-1:2010) | |
CSA-C22.2 No. 61010-1-04 | |
UL 61010-1 (3rd Edition) and 508 | |
Performance | EN 50271:2010; EN 60079-29-1:2016; EN 45544-1 /-2 /-3:2015; EN 50104:2010 C22.2 No. 152-M1984, ISA 12.13.01 |
Safety Integrity | IEC 61508:2010 Ed.2 SIL2, EN 50271:2010 |
Hazardous Location | Class I, Division 2, Group A, B, C and D or non-hazardous only |
Marine | MED (Item No.: 3.54) |
Others | |
Backup battery | 22.2V Lithium Ion Battery, 2600mAh capacity (>30 minutes for typical system) |
Data logging | Configuration, logged events and data |
Communication | MODBUS TCP, WEB monitoring and MODBUS RTU |
Touchpoint Plus Datasheet
Touchpoint Plus Specification Sheet
Touchpoint Plus User Guide
Touchpoint Plus Technical Manual
Touchpoint Plus Specification Sheet
Touchpoint Plus User Guide
Touchpoint Plus Technical Manual