Sensepoint


Sensepoint with Junction Box

The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs, indoors or out and even in potentially explosive atmospheres (ATEX approval only). Supplied with a pre-wired junction box, the detector can be installed using conduit or armored cable and glands depending on individual site standards. The junction box includes a hinged lid to ensure both hands are free to complete electrical connections. Threaded M20 as well as 3/4" and 1/2” NPT clearance entries are included as standard, each one fitted with an appropriate seal, so enabling the user to select the most convenient entry size to use.
Fit For Purpose

• Flammable, toxic and Oxygen versions available

• High performance, low cost

• Suitable for new and retrofit applications

Proven Sensor Technology

• Surecell electrochemical sensors

• Poison resistant catalytic bead

• Fast and reliable

• Typical 2 to 5 years operational life

ATEX Certified

• Complies with the latest European standards

• Hazardous area approval and performance

• IP65 / 66 for use in harsh environments

• Factory set operation

• Simple to replace

• Minimal training required

Range of Accessories

• Weatherproof cap

• Flow adaptor

• Duct mounting kit

• Collecting cone
General specification
UseCost-effective, fixed point gas detector for the protection of personnel and plant from flammable, toxic and Oxygen gas hazards
Detectable gases
GasMeasuring rangeOperating temperature
IdentifierName123MinMax
FFlammable0-100% LEL-40°C / -40°F50°C / 122°F
OOxygen0-25% VOL-15°C / 5°F40°C / 104°F
CCarbon Monoxide0-200 ppm0-500 ppm-20°C / -4°F50°C / 122°F
HHydrogen Sulfide0-50 ppm0-20 ppm0-100 ppm-25°C / -13°F50°C / 122°F
GHydrogen0-1000 ppm-5°C / 23°F40°C / 104°F
LChlorine0-5 ppm0-15 ppm-20°C / -4°F50°C / 122°F
SSulfur Dioxide0-15 ppm0-50 ppm-15°C / 5°F40°C / 104°F
NNitrogen Dioxide0-10 ppm-15°C / 5°F40°C / 104°F
AAmmonia0-50 ppm0-1000 ppm-20°C / -4°F40°C / 104°F
Construction
ElectricalFlammable (0-100% LEL)Toxic & OxygenJunction Box
3 wire mV bridge2 wire loop powered 4-20mA (plus screen)Earth continuity plate
2.9-3.5V, 0.7W16-30 Vdc, 0.9WBK4 terminal block (4 way
200mA constant current4 x 0.5mm2 (20AWG) to 2.5mm2 (14AWG)
1 x M20, 1 x ¾” NPT, 1 x ½” NPT
MaterialPolyphenylene Sulfide (PPS)Polyphenylene Sulfide (PPS)Fire retardant GFP
Weight190g185g (205g Oxygen)600g
CertificationEx II 2GDEx II 2 GD Ex d ia IIC T4 Gb Tamb -40ºC to +65ºCEx II 2GD
Ex d IIC T6 GbEx tb IIIC A21 IP67 T135ºC DbEx e IIC T6 Gb Tamb -40ºC to +50ºC
Ex tb IIIC A21 Db IP67 T85ºCBaseefa08ATEX0263XEx t IIIC T85ºC Db IP66
(Tamb -40ºC to +55ºC) or T100ºCIECEx BAS08.0070XSira 06ATEX3185
(Tamb -40ºC to +70ºC) or T135ºC
(Tamb -40ºC to +80ºC)
Baseefa08ATEX0265X
IECEx BAS08.0068X
Applicable standardsThis product complies with the relevant CE standards including: EMC to EN50270, Flammable to EN60079-29-1, Toxic to EN445544 (H2S only)
Environmental
IP ratingIP65 standard, IP66 with weather protection in accordance with EN60529:1992
Operating temperatureDependent upon gas type and certification
Operating humidity rangeContinuous:20-90% RH (non condensing)
Intermittent:10-99% RH (non condensing)
Operating pressure90-110kPa
Storage conditionsInstrument -40°C to +50°C (-40°F to +122°F)
Ordering Information
Standard SupplyEach detector is supplied complete with junction box, multiple cable entries, earth continuity plate, hinged lid and instruction leaflet, all sealed in a plastic bag inside a shipping carton
Shipping DetailsShipping carton dimensions:Length:6.3 in. (160 mm)
Width:8.5 in. (215 mm)
Depth:3.1 in. (80 mm)
Optional Accessories02000-A-1645Calibration gas flow housing (for flammable & toxic)
00780-A-0160Right angle mounting bracket for ceiling mounting
02000-A-1640Weather Housing for use with flammable detector including remote gassing nozzle
02000-A-1635Weather Housing for use with toxic/Oxygen detector including remote gassing nozzle
02000-A-1642Collecting cone for use with flammable detector
Calibration EquipmentContact Honeywell Analytics Representative
Gas & RangeFlammable 0-100% LEL
Flammable PPM (Typically 0-10% LEL)Hydrogen Sulfide (H2S) 20/50/100 ppmCarbon Monoxide (CO) 100/200/500 ppmAmmonia (NH3) 50/1000 ppmChlorine (Cl2) 5/15 ppmOxygen (O2) 25% V / V
Hydrogen (H2) 1000/10000 ppmSulfur Dioxide (SO2) 15/50ppmNitric Oxide (NO) 100ppmNitrogen Dioxide (NO2) 10ppm
Operating Temp-40 to +80˚C-30 to +65˚C-25 to +50˚C-20 to +50˚C-20 to +40˚C-20 to +50˚C-15 to +40˚C-15 to +40˚C-15 to +40˚C-15 to +40˚C-15 to +40˚C
Operating HumidityContinuous:20 to 90% RH (non-condensing)
Intermittent:10 to 99% RH (non-condensing)
Storage Conditions0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH0 to 25˚C; 30 to 70% RH
Operating Pressure90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa90 to 110kPa
Warm-up Time< 10 minutes< 20 minutes< 3 minutes< 3 minutes< 3 minutes< 5 minutes< 5 minutes< 3 minutes< 3 minutes12 hours1 hour
Response Time
T20< 6 secs< 5 secs< 10 secs< 3 secs< 3 secs< 15 secs
T50< 5 secs< 5 secs< 15 secs< 12 secs< 10 secs< 20 secs< 5 secs< 10 secs< 10 secs< 5 secs< 30 secs
T90< 10 secs< 10 secs< 40 secs< 30 secs< 65 secs < 105 secs< 10 secs< 45 secs< 90 secs< 30 secs< 60 secs
Supply200mA; 0.7W maximum18 to 30VDC; 0.9W maximum
Signal OutputmV bridgeLoop powered 4-20mA
Linearity< 5% fsd or ±10% of reading< 5% fsd
Operating Life5 years (typical)2 years (typical)18 months (typical)1 year (typical)18 months (typical)
Storage LifeTypically, over 5 years when in original sealed packaging6 months6 months6 months6 months6 months6 months6 months6 months6 months
Stability (zero)
with time< ±3% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr< ±2% fsd / yr
with temperature< ±1% fsd2< ±3% fsd< ±5% fsd< ±6% fsd< ±2% fsd< ±2% fsd< ±5% fsd< ±5% fsd< ±5% fsd
with humidity< ±1% fsd< ±10% fsd< ±2% fsd< ±10% fsd< ±2% fsd< ±2% fsd< ±10% fsd< ±10% fsd< ±10% fsd
Stability (span)
with time< ±3% fsd / yr< ±2% fsd / yr< ±4% fsd / yr< ±20% fsd / yr< 10% fsd / yr< ±20% fsd / yr< ±2% fsd / yr
with temperature< ±3% fsd< ±8% fsd< ±25% fsd< ±20% fsd< ±20% fsd< 40% fsd< ±10% fsd< ±60% fsd< ±15% fsd< ±25% fsd
with humidity< ±2% fsd< ±10% fsd< ±2% fsd< ±10% fsd< ±2% fsd< ±1% fsd< ±2% fsd< ±10% fsd
Weight190g190g185g185g185g185g205g185g185g185g185g
Construc. MaterialsPolyphenylene Sulfide (PPS)
I.P. (NEMA) RatingIP65 (standard), IP67 (with weather protection fitted)
Certification Details (ATEX/ IECEx)Ex II 2 GD Ex d IIC Gb T85ºC Tamb -40ºC to +55ºCEx II 2 GD Ex d ia IIC T4 Gb Tamb -40ºC to +65ºC
Ex II 2 GD Ex d IIC Gb T100ºC Tamb -40ºC to +70ºCEx tb IIIC A21 IP67 T135ºC Db
Ex II 2 GD Ex d IIC Gb T135ºC Tamb -40ºC to +80ºCBaseefa08ATEX0263X
Ex tb IIIC A21 Db IP67IECEx BAS08.0070X
Baseefa08ATEX0265X
IECEx BAS08.0068X
Other CertificationsRussian:GOST
Applicable Standards This product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1