Searchzone Sonik
Searchzone Sonik
The Honeywell Searchzone Sonik is a robust and reliable gas-leak detection device that will efficiently “hear” the loss of containment of any high-pressure gas within its listening zone. As it responds to the ultrasonic sound pressure level produced by pressurized gas leaks, it is therefore unaffected by environmental conditions.
Searchzone Sonik is factory calibrated. Its robust sealed design with no moving parts and the advanced solid-state sensor allow for mounting in any orientation, even in the harshest environments. The acoustic gas leak detector will respond quickly to a gas leak within a sensing range radius of typically 20m (65 ft), dependent upon background noise.
No False Alarms– the high-end spectral analysis delivers best-in-class detection of high-pressure gas leaks in real-world environments.
Wide Zone Coverage– typically 20m (65 ft) detection radius, dependent upon background ultrasonic noise levels.
Complements Existing Gas Detectors– the Searchzone Sonik seamlessly integrates with existing point-and-open path gas detectors, thus creating the optimal gas detection mix.
No Moving Parts– the solid-state sensor works flawlessly even in the harshest environments and doesn’t need additional calibration.
Simple Installation and Alignment– the Platform Universal Mount with 3 graduated degrees of freedom enables easy mechanical set-up.
Bluetooth Compatibility– set-up and interrogation from ground level are available via Bluetooth by using the Honeywell Platform application on IS mobile phones. Depending on the mobile device, the range can reach up to 20 m (65 ft).
Instrument Status at a Glance– the Searchzone Sonik features a bright signal light – green, yellow, red, or blue - providing clear indication of the instrument status.
Full Operational Logs– enables post-event analysis to assess overall performance and allows security checks.
Fast Commissioning– the Searchzone Sonik App allows users to save configurations and upload to other Searchzone Soniks for quick and easy commissioning.
Searchzone Sonik is factory calibrated. Its robust sealed design with no moving parts and the advanced solid-state sensor allow for mounting in any orientation, even in the harshest environments. The acoustic gas leak detector will respond quickly to a gas leak within a sensing range radius of typically 20m (65 ft), dependent upon background noise.
No False Alarms– the high-end spectral analysis delivers best-in-class detection of high-pressure gas leaks in real-world environments.
Wide Zone Coverage– typically 20m (65 ft) detection radius, dependent upon background ultrasonic noise levels.
Complements Existing Gas Detectors– the Searchzone Sonik seamlessly integrates with existing point-and-open path gas detectors, thus creating the optimal gas detection mix.
No Moving Parts– the solid-state sensor works flawlessly even in the harshest environments and doesn’t need additional calibration.
Simple Installation and Alignment– the Platform Universal Mount with 3 graduated degrees of freedom enables easy mechanical set-up.
Bluetooth Compatibility– set-up and interrogation from ground level are available via Bluetooth by using the Honeywell Platform application on IS mobile phones. Depending on the mobile device, the range can reach up to 20 m (65 ft).
Instrument Status at a Glance– the Searchzone Sonik features a bright signal light – green, yellow, red, or blue - providing clear indication of the instrument status.
Full Operational Logs– enables post-event analysis to assess overall performance and allows security checks.
Fast Commissioning– the Searchzone Sonik App allows users to save configurations and upload to other Searchzone Soniks for quick and easy commissioning.
- Increases ease of use with advanced set-up and test tools.
- Enables quicker, easier installation
- Minimizes the risks of false alarms
- Minimizes cost of ownership and saves time
- Maximizes the safety and efficiency of your mix of fixed gas detectors
- Provides reliable gas leak detection in a wide range of applications and working environments
PRODUCTION
• Exploration vessels
• Wellheads
• Compressors
• Metering skids
• Valves
STORAGE
• Pumps
• Valves
• Seals
GATHERING AND PROCESSING
• Compressors
• Processing plant
• Turbines
• Gas safety valves
TRANSMISSION AND DISTRIBUTION
• Compressors
• Pipelines
• Metering stations
• Valves
• Exploration vessels
• Wellheads
• Compressors
• Metering skids
• Valves
STORAGE
• Pumps
• Valves
• Seals
GATHERING AND PROCESSING
• Compressors
• Processing plant
• Turbines
• Gas safety valves
TRANSMISSION AND DISTRIBUTION
• Compressors
• Pipelines
• Metering stations
• Valves
GENERAL | ||
Manufacturer | Honeywell | |
Model | Searchzone Sonik Ultrasonic Gas Leak Detector | |
Part Numbers | SZSK-SMGXX | |
SZSK-SNGXX | ||
GAS DETECTOR SPECIFICATIONS | ||
Sensor Type | Tuned piezoelectric transducer | |
Detection Method | Sound Pressure Level at sensor | |
Frequency Range | 18 kHz to 70 kHz | |
Dynamic Range | 60 dB to 120 dB (detectable range of 40 dB to 140 dB) | |
Calibration | Factory calibrated (no field calibration required) | |
Detector Range | Typically 20 m (Standard Mode) or 7m (Focus Mode) on-axis. Background noise dependent. Reference the manual. | |
Recommended Alarm Setting | 6 dB above background noise | |
Cone of Detection | +/- 90 degrees (Standard Mode) | |
+/- 20 degrees (Focus Mode) | ||
Speed of Response | Sensor response 1 second | |
Programmable Verification time from 1 to 600 seconds | ||
Electronic Self Test | Built in test diagnostics | |
Storage Temperature | -55° C to +75° C (-67 °F to +167 °F) | |
Operating Temperature | -55° C to +75° C (-67 °F to +167 °F) | |
Operating Humidity | 0 to 100% Relative Humidity Condensing | |
Warm-up Time | Less than 5 minutes (operational) | |
Power Supply & Maximum Power Consumption | 24Vdc nominal (18 Vdc to 32 Vdc) | |
4W for ambient operating temperature -30°C and above, 15 W for ambient operating temperature below -30°C (heater is active) | ||
Cable entries | 2 x M25 or 2 x 3/4” NPT | |
Relays | Relays (1 fault, 2 Alarm) – Max. 32 Vdc/ac, max. 2 A resistive load. | |
Analog Output Signal | 4–20 mA Normal operation, 1 mA Fault, 2 mA Inhibit, 3 mA Warning, 21 mA Overrange. Isolated, sink or source. | |
Linear configurable output corresponding to Sound Pressure Level or discrete mode. | ||
Digital Communications | Modbus RTU RS-485. | |
HART with handheld communicator or hardwired. | ||
Bluetooth to smartphone or tablet. | ||
Event Logs | Time stamped | |
Visual Indication | High Visibility LED; green/yellow/red/blue to indicate detector status | |
Green (normal) indication can be disabled via Searchzone Sonik App. | ||
Dimensions and Weight | Instrument: | 103 dia x 235 x 179 mm, 6.1 kg (13.5 lbs) |
Standard Mount: | 165 x 165 x 127 mm, 2.9 kg (6.4 lbs) | |
Large Mount: | 210 x 210 x 127 mm, 3.5 kg (7.7 lbs) | |
Enclosure Material | Stainless Steel 316L; with paint finish | |
Standard or Large Mounting Bracket | Stainless Steel. Graduated to enable Searchzone Sonik to be simply mounted and aimed in 5 degree steps | |
Interfaces | Bluetooth non-intrusive connection to suitable mobile device running the Searchzone Sonik mobile app. | |
Range up to 20 m (mobile device dependent). | ||
Vibration | 2 - 60 Hz, maximum peak to peak amplitude 1 mm | |
Ingress Protection (IP) Rating | IP 66 / 67 (Type 4X), according to NEMA 250 | |
Core Approvals | EN 50270: 2015 (EMC) | |
IEC/EN 61000-6-4; EMC Directive 2014/35/EU | ||
IEC/EN/UL/CSA 61010 (Electrical Safety) | ||
FCC | ||
RoHS, China RoHS | ||
Safety Approvals | ATEX | Ex II 2 GD |
Ex db ia IIC T4 | ||
Ex tb IIIC T85°C | ||
Ex db eb ia IIC T4 | ||
Tamb -55 to +75°C (-67 to 167 °F) | ||
cULus | Class I, Div 1, B, C & D | |
Class II/III, E, F & G (pending) | ||
Tamb -55 to +75°C | ||
Class I Zone 1 AEx d ia IIC T4 (USA) | ||
Class I Zone 1 Ex d ia IIC T4 (Canada) | ||
IECEx | Ex d b ia IIC T4 | |
Ex tb IIIC T85°C | ||
Ex db eb ia IIC T4 | ||
Tamb -55 to +75°C (-67 to 167 °F) | ||
Marine Approvals | Type approved to DNV, BV, Lloyds, ABS Location Classes: Temp B, Humidity B, Vibration A & C, EMC B | |
Other Approvals | BT SIG (Bluetooth), RED, FCC+, country-specific wireless approvals | |
EN 61508:2010 SIL2 -55 °C to +75 °C, independently assessed by TÜV | ||
CCCF | ||
INMETRO | ||
Bluetooth communication security | Certificate-based mutual authentication. Encryption to AES128 | |
Warranty Period | 36 months from date of shipment. | |
ACCESSORIES | ||
Adjustable Mounting Bracket | Standard bracket (included). Large bracket (optional), 2331B1112 | |
Sunshade | Plastic (included), stainless steel sunshade (optional), 2331B1131 | |
Hand-Held Tester | Ultrasound-generating device used for functional verification, 2331B1000 | |
Hand Held Communicator | I.S. Android Smartphone. Download the Searchzone Sonik App |
Searchzone Sonik Brochure
Searchzone Sonik Specification Sheet
Searchzone Sonik Quick Start Guide
Searchzone Sonik Technical Manual
Searchzone Sonik Specification Sheet
Searchzone Sonik Quick Start Guide
Searchzone Sonik Technical Manual