Honeywell MIDAS Sensor Cartridge for Nitrogen Trifluoride (NF3) 0-40ppm, Methyl Fluoride (CH3F) 0-120ppm (all require Pyrolyzer)

$414.00

Description

Honeywell MIDAS Sensor Cartridge for Nitrogen Trifluoride (NF3) 0-40ppm, Methyl Fluoride (CH3F) 0-120ppm (all require Pyrolyzer)

Several Honeywell MIDAS® cartridges can be configured to read a number of different gases based on a common chemical family. Actual details for the sensor detection range are included in the sensor cartridge specification sheet and the MIDAS® technical manual. MIDAS® sensor cartridges can be ordered as part of a Kit with the universal MIDAS® transmitter, or as a replacement part. The detectable range is listed. With the exception of O2 (where ambient concentration is typically 20.9%), the sensors will display zero when no gas is present. All Cartridges with the format MIDAS-E-XXX are supplied with a 2 year (24 month) warranty.
Gas MeasuredNitrogen Trifluoride (NF3)
Cartridge Part NumberMIDAS-E-XHF2 year extended warranty
Sensor Technology3 electrode electrochemical cell
Measuring Range (ppm)NF30 - 40 ppm
Minimum Alarm 1 Set Point4.0 ppm
Repeatability< ± 10% of measured value
Linearity< ± 20% of measured value
Response Time t62.5< 110 seconds
Sensor Cartridge Life Expectancy≥ 24 months under typical application conditions
Operating Temperature0°C to +40°C (32°F to 104°F)
Effect of Temperature< ± 0.002ppm / °C (at 0°C to 20°C)
Zero< ± 0.008ppm / °C (at 20°C to 40°C)
Sensitivity< ± 0.4% of measured value / °C
Operating Humidity (continuous)20 – 75% rH
Effect of HumidityZero< ± 0.003ppm / % rH
Sensitivity< ± 1% of measured value / % rH
Operating Pressure90 – 110kPa
Effect of PositionNo effect in typical application
Long Term DriftZeroNo Drift
Sensitivity< 15% of measured value / year
Calibration GasHydrogen Fluoride (HF)
Challenge Gas (Bump Test)Nitrogen Dioxide (NO2)
Warm Up Time< 20 minutes
Storage Temperature+5°C to +25°C (+41°F to +77°F)
Other Detectable GasesThe following additional gases can be detected with this sensor cartridge. Sensor performance and characteristics will be representative of the data as tabulated above. Consult the Technical Manual to set up the Midas transmitter with the designated identification code for each of the following gas types.
Detectable GasChemical FormulaMeasuring Range
Methyl FluorideCH3F0 – 120ppm
Cross Sensitivities

Each Midas sensor is potentially cross sensitive to other gases and this may cause a gas reading when exposed to other gases than those originally designated. The table below presents typical readings that will be observed when a new sensor cartridge is exposed to the cross sensitive gas (or a mixture of gases containing the cross sensitive species).
Gas / VaporChemical FormulaConcentration applied (ppm)Reading (ppm NF3)
ArsineAsH310
Carbon MonoxideCO20000
ChlorineCl2513.7
DiboraneB2H61-1.3
HydrogenH2200000
Hydrogen ChlorideHCl814
Hydrogen FluorideHF28
Hydrogen SulfideH2S25-3.6
Iso PropanolC3H7OH5000
MethanolCH3OH 5000
Nitrogen DioxideNO252.6
PhosphinePH31-0.14
Sulfur DioxideSO21022.8

Additional information

Weight 1 lbs