Gasclip Multi Gas Clip 4 Gas detector with internal pump & pellistor LEL sensor

$995.00

Description

Detects hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2 ) & combustible gases (LEL).

Multi Gas Clip Pump

A New Option in Portable Gas Detection

Twice a day, every day… that’s how often you have to charge most portable gas detectors, until now. The Multi Gas Clip Pump (MGC Pump) from Gas Clip Technologies is the only portable multi gas detector with an internal sampling pump that can run 52 hours continuously without a charge.

A Long-Lasting Family Tradition

The MGC Pump follows in the long line of portable gas detectors by Gas Clip Technologies that last and last and last. Being able to go a long time between charges is a family tradition.

The Secret to a Long Life

Like our MGC, the MGC Pump uses low-power photometric infrared technology to detect combustible gases (LEL) rather than age-old pellistor technology. The MGC Pump uses an IR source which conserves power and helps the battery last and last.

Ergonomic Design Makes for a Good Fit

The MGC Pump is also designed for comfort. The reduced, sloping shape of the holding area at the bottom of the instrument makes the MGC Pump a comfortable fit in the hands of your workers. It is fully submersible and simple to operate. The MGC Pump offers a one button design and the largest LCD screen in the industry so it’s easy to read.

Calibrate the MGC Pump Once Every 12 Months

Other multi gas detectors require calibration anywhere from 1 to 3 months. The MGC Pump can go 12 months without being calibrated. This is an added benefit of IR sensing technology because IR is immune to pellistor sensor poisons such as silicone or H2S.
  • 52 hour continuous run time
  • 1 year calibration cycle
  • Will work in inert environments, no need for oxygen
  • Draws up to 75 feet
  • Stainless steel gas inlet
Size5.7 x 3.0 x 1.5 in. (147 x 78 x 38.3 mm.)
Weight12.4 oz. (352 g)
Temperature-4˚F to +122˚F (-20˚C to +50˚C)
Humidity5% to 100% RH (non-condensing)
Battery LifeIR5 days continuous
Pellistor30 hours continuous
Charge Time4-6 hours
AlarmsVisual, Vibrating, Audible (minimum 95dB) Low, High, STEL, TWA, OL (Over Limit), Pump
LEDs4 red alarm bar LEDs
Yellow backlight (activated on button press)
Red backlight (activated on alarm condition)
Yellow Maintenance Notification LED
DisplayAlphanumeric Liquid Crystal Display (LCD)
Logs25 Bump Tests
25 Events
25 Calibrations
Continuous 1-second data logging (> 2 months typical capacity)
TestsFull function self-test upon activation
Sensors, battery and circuitry continuous
Ingress ProtectionIP 67
WarrantyFull 2 years
Gas Inlet1/8” barbed fitting
Pump drawSample from up to 75 ft. (23 m), approximately 2 ft/second with 1/8” tubing
GasesH2S0 – 100.0 PPM (0.1 PPM increments)
CO0 – 500 PPM (1 PPM increments)
Combustible0 – 100.0 %LEL (0.1% LEL increments)
O20 – 30.0 % vol. (0.1% vol. increments)
Sensor TypeH2S, CO, O2Single plug-in electrochemical cell
CombustiblePlug-in Infrared (IR) or Pellistor
User OptionsUser Message, Language, Low Alarm, High Alarm, STEL Alarm, TWA Alarm, TWA Method, TWA Interval, STEL Interval, SAFE, Maintenance Notification, Self-test Lock, Dock Lock, Pump Test, Sensor Enable, Calibration Interval, Bump Interval, Calibration Gas
ApprovalsCSAClass 1, Division 1, Group A, B, C, and D Class 1, Zone 0, AEx ia IIC T4 Ga C22.2 No.’s 0, 152, 157
IECExEx ia IIC T4 Ga IECEx CSA xx.xxxxx IEC 60079-0:2011, 60079-11:2011, 60079-26:2006
ATEXSIRA 13 ATEX ****X CE II 1 G Ex ia IIC T4 Ga EN 60079-0:2012, 60079-11:2012, 60079-26:2007 EN 50270 ANSI/ISA S12.13.01 UL-913
INMETRONCC xx.xxxxx Ex ia IIC T4 Ga (-20°C ч Ta ч 50°C)