The Beacon 200 is a powerful, low cost fixed system controller for two points of gas detection.
It is microprocessor controlled, versatile, simple to install and operate, and priced to be the industry’s most economical two point controller. It is capable of connecting directly to RKI sensors for LEL level combustibles, Oxygen, Hydrogen Sulfide, or Carbon Monoxide. The Beacon 200 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 200 housing, or can be wired remotely from the controller.
The 10 amp rated relays are strong enough to actuate most external alarms and horns without using slave relays. The digital display has backlighting and simultaneous readout of the gas type and concentration.
The Beacon 200’s housing is rated NEMA 4X for corrosion resistance and a weather tight seal, and complies with lock out / tag out standards. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 200 comes complete with a wall mounting kit for easy installation.
RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilized with the Beacon 200, providing gas monitoring protection for almost any application.
Simultaneous readout on 2 channels
Two alarm levels per channel
Discrete and common relays
NEMA 4X enclosure
4-20 mA outputs
Proven, long-life sensors for a wide variety of gases
Accepts any 4-20 mA transmitter input (24 VDC)
Easy to install, operate and expand
Petrochemical plants
Refineries
Water & wastewater treatment plants
Pulp & paper mills
Gas, telephone, & electric utilities
Parking garages
Manufacturing facilities
Steel
Automotive
HVAC
Physical
Dimensions
Height: 10.5” (267 mm)
Width: 8.5” (216 mm)
Depth: 6.3” (158 mm)
Enclosure
Wall mounting grey polycarbonate with hinged cover
Conduit Connection
3/4” NPT conduit hubs, 3 provided. 2 for sensor wiring and 1 for power & relay wiring
Wiring Termination
Screw type terminal block, 14 gauge max
Controls
4 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset
Environmental
Operating Temp
-4°F to 122°F (-10°C to 50°C)
Storage Temp
-4°F to 158°F (-20°C to 70°C)
Relative Humidity
0 – 100% RH
Enclosure Rating
NEMA-4X enclosure, waterproof, chemical, and weather resistant
Inputs
Direct Wired Sensors
LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide Remote amp not required for less than 500 feet
4-20 mA Sensors
Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet
Sampling Methods
Diffusion and sample draw heads available
Outputs
Relays
7 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarm levels per channel, plus 2 relays for common gas alarm and 1 common relay for malfunction. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off
4-20 mA
Signal output, 4-20 mA (into 1000 ohms impedance maximum), per channel
24 VDC
24 VDC (350 mA max) output provided to operate sample drawing adapters or other accessories
Display
Alphanumeric display with backlighting. 20 characters per line; 4 lines each
Audible
Built-in audible alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail
Visual
4 LED’s on the front cover for alarm status indication, pilot, and malfunction
Optional Expansion Cards
Individual 4-20 mA (or 1 – 5 VDC) outputs Heavy duty relay card (4 each @ 30 amps)
Power
110-240 VAC or 24 VDC standard. Battery backup option available
Warranty
One year materials and workmanship
Partial List Of Detectable Gases