Beacon 800, eight channel controller (no sensors)

$2,700.00

Description

Beacon 800 72-2108RK

Gas detection should not be complicated. The Beacon 800 is gas detection simplified.

The Beacon 800 is a versatile, low cost fixed system controller for one to eight points of gas detection. It is microprocessor controlled and is capable of accepting up to 8 separate 4-20 mA sensor transmitters which can be either 2 or 3 wire. The Beacon 800 can be powered by either 24 VDC, or 85-264 VAC. It is simple to operate and comes complete with a wall mount installation kit.

The 2 large digital displays have backlighting and easily identify both the gas type and the gas concentration for all 8 channels simultaneously. The Beacon 800 is housed in a NEMA 4X rated case for a weather tight seal. This case design complies with lock out / tag out standards and can be fully secured. An external reset switch allows alarms to be silenced from outside the controller housing. The bottom mounted wiring hubs allow for easy wiring.

With 3 amp rated relays, the Beacon 800 can be wired directly to a variety of devices like alarm horns, buzzers, or lights. This eliminates the need for costly external relays from the controller to devices. RKI offers the industry’s widest selection of standard and toxic gas detection sensors, which can be utilized with the Beacon 800, providing gas monitoring protection for almost any application.

  • Capable of up to 8 separate channels
  • Digital display of all 8 channels simultaneously
  • Compact, weatherproof, NEMA 4X enclosure
  • 85 to 264 VAC or 24 VDC operation
  • Long life sensors (2+ years typical)
  • Accepts any 4-20 mA transmitter
  • Audible alarm with reset button
  • Two programmable alarm levels per channel
  • Common alarm and fail relays
  • Relay rating 3 amps, form C
  • Low cost versatile solution
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment pants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC
Physical
DimensionsHeight12.5″ (318 mm)
Width11.0″ (279 mm)
Depth 6.4″ (163 mm)
EnclosureWall mounting grey polycarbonate with hinged cover.
Conduit Connection3/4″ NPT conduit hubs, 4 provided for sensors, power and relay wiring.
Wiring TerminationScrew type terminal block, 14 gauge max.
Environmental
Operating Temp-4°F to 122°F (-10°C to 50°C)
Storage Temp-4°F to 158°F (-20°C to 70°C)
Relative Humidity0 – 100% RH
Enclosure RatingNEMA-4X enclosure, waterproof, chemical, and weather resistant.
Inputs
4-20 mAAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI sensors are available with4-20 mA signals. Wiring distances up to 8,000 feet.
Outputs
Relays2 relays per channel 10 amp rating, SPDT isolated contacts
1 set of common relays2 for gas alarm levels
1 for malfunction
Relays fully programmable forIncreasing or decreasing alarms
Latching or self reset
Normally energized or normally de-energized
Time delay for alarm on and alarm off
Display2 alphanumeric displays with backlighting. 16 characters per line; 4 lines each. All 8 channels continuously displayed.
AudibleBuilt-in audible alarm, 94 dB steady tone, mounted on enclosure.
Visual4 visual LED alarms on front cover for alarm indications, pilot, and malfunction.
Optional Expansion CardsIndividual 4-20 mA (or 1 – 5 VDC) outputs Heavy duty relay card (4 each @ 30 amps)
Power85-264 VAC or 24 VDC standard
Battery backup option available
ApprovalsCSA Certified to CSA C22.2 No. 1010 and ANSI/ISA S82.01
WarrantyOne year materials and workmanship.
Partial List Of Detectable GasesMany other gases or ranges available. Contact us for gases or ranges not listed.
Ammonia (NH3)0 – 75.0 ppm
Arsine (AsH3)0 – 0.20 ppm
Boron Trichloride (BCl3)0 – 15.0 ppm
Carbon Dioxide (CO2)0 – 1.0 %
Carbon Monoxide (CO)0 – 300 ppm
Chlorine (Cl2)0 – 3.0 ppm
Chlorine Dioxide (ClO2)0 – 1.00 ppm
Chlorine Trifluoride (ClF3)0 – 1.00 ppm
Combustibles0 -100% LEL
Diborane (B2H6)0 – 30.0 ppm
Fluorine (F2)0 – 6.0 ppm
Hydrogen (H2)0 – 2000 ppm
Hydrogen Chloride (HCl)0 – 15.0 ppm
Hydrogen Fluoride (HF)0 – 9.0 ppm
Hydrogen Sulfide (H2S)0 -100.0 ppm
Nitric Oxide (NO)0 -100.0 ppm
Nitrogen Dioxide (NO2)0 – 15.0 ppm
Nitrogen Trifluoride (NF3)0 – 30.0 ppm
Oxygen (O2)0 – 25.0%
Ozone (O3)0 – 1.0 ppm
Phosphine (PH3)0 – 1.0 ppm
Silane (SiH4)0 – 15.0 ppm
Sulfur Dioxide (SO2)0 – 30.0 ppm
TEOS (Si(OC2H5)4)0 -15/30 ppm

Additional information

Weight 14 lbs
Dimensions 20 × 15 × 9 in